Original Factory Sharp Edge Tester - GC-7890 Ditert-butyl Peroxide Residue Detector – Yueyang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We offer great strength in quality and development,merchandising,sales and marketing and operation for Multi-Function Rubber Rheometer, Fabric Friction Tester, Corrugated Lifting Device, We welcome new and previous customers from all walks of lifestyle to contact us for long run organization relationships and mutual achievements.
Original Factory Sharp Edge Tester - GC-7890 Ditert-butyl Peroxide Residue Detector – Yueyang Detail:

Melt-blown cloth has the characteristics of small pore size, high porosity and high filtration efficiency, and is the core material of mask production. This instrument refers to GB/T 30923-2014 plastic Polypropylene (PP) Melt-blown Special Material, suitable for polypropylene as the main raw material, with di-tert-butyl peroxide (DTBP) as the reducing agent, modified polypropylene melt-blown special material.

The sample is dissolved or swollen in toluene solvent containing a known amount of n-hexane as internal standard. An appropriate amount of solution was absorbed by microsampler and directly injected into gas chromatograph. Under certain conditions, gas chromatographic analysis was carried out. DTBP residue was determined by internal standard method.

1) Gas chromatograph, Capillary column inlet, FID detector,

2) Analyze the balance

3) Capillary column: AT.624 30m*0.32mm*1.8μm,

4) Chromatographic workstation software,

5) N-hexane, chromatographic pure;

6) Di-tert-butyl peroxide, analytically pure;

7) Toluene, analytical pure.

GC-7890 Gas chromatograph adopts microcomputer control system and Chinese large screen display, the appearance is more beautiful and smooth. The newly designed keyboard keys are simple and fast, and the circuits are imported components, so the instrument performance is stable and reliable.

. High circuit integration, high precision, multi-function

 1. All-microcomputer key operation, 5.7 inch (320*240) large LCD display in Chinese and English, Chinese and English display can be switched freely, to meet the requirements of different groups of people, man-machine dialogue, easy to operate.

2.Microcomputer control hydrogen flame detector to achieve automatic ignition function, more intelligent. New integrated digital electronic circuit, high control precision, stable and reliable performance, up to 0.01℃ temperature control precision.

3.Gas protection function, protect the column and thermal conductivity pool, electron capture detector.

It has the function of self-diagnosis on startup, which enables users to quickly know the cause and position of instrument failure, stopwatch function (convenient flow measurement), power failure storage and protection function, anti-power mutation interference function, network data communication and remote control function. The overtemperature protection function is guaranteed

The instrument is not damaged and has a data memory system that does not require every reset.

.Injection system unique design, can be lower detection limit

1. Unique injection port design to solve injection discrimination; The double column compensation function not only solves the base-line drift caused by temperature programmed, but also subtracts the influence of background noise to obtain a lower detection limit.

2.With packed column, capillary shunt/non-shunt injection system (with diaphragm cleaning function)

3.Optional automatic/manual gas six-way injector, headspace injector, thermal resolution injector, methane converter, automatic injector.

 

Ⅲ、Temperature programmed, precise furnace temperature control, fast stability

1.Eight-order linear temperature programmed, after the door using photoelectric switch contactless design, reliable and durable, intelligent after the door system stepless variable air volume, shorten the program after the rise/drop of the detector system stable balance time, really realize the near room temperature operation, temperature control accuracy of ±0.01℃, meet the requirements of wide range of analysis.

2.Large volume of the column box, intelligent rear door system stepless variable air volume in and out, shorten the program after lifting/cooling the detector system stable balance time; Heating furnace system: ambient temperature +5℃ ~ 420℃.

3.The insulation effect is better: the column box, vaporization, detection are 300 degrees, the outer box and the top cover is less than 40 degrees, improve the experimental rate, to ensure the safety of the user.

4.Unique design of vaporization chamber, smaller dead volume; Accessories replacement: injection pad, liner, polarizer, collector, nozzle can be replaced with one hand; Main body replacement: filling column, capillary sampler and detector can be completely removed with only a wrench, easy maintenance.

High sensitivity, high stability detector, meet the needs of different schemes

Hydrogen flame ionization detector (FID), thermal conductivity cell detector (TCD), electron capture detector (ECD),

Flame Photometric detector (FPD), Nitrogen and Phosphorus detector (NPD)

All kinds of detectors can be independently controlled temperature, hydrogen flame detector is easy to disassemble and install, easy to clean or replace the nozzle.

Injection port

A variety of injection ports available: filled column injection, shunt/non-shunt capillary injection

Column temperature box

Temperature range: room temperature +5~420℃

Temperature setting: 1 degree; Programmed temperature rise rate 0.1 degree

Maximum heating rate: 40 degrees/min

Temperature stability: 0.01 degree when the ambient temperature changes 1 degree

Temperature programmed: 8 order temperature programmed can be adjusted

Hydrogen flame ionization detector (FID)

Operating temperature: 400℃

Detection limit: ≤5×10-12g/s (n-hexadecane)

Drift: 5 x 10-13 a / 30 min or less

Noise: 2 x or less 10 to 13 a

Dynamic linear range: ≥107

Size: 465*460*550mm, weight: 40kg,

Input power: AC220V 50HZ maximum power 2500W

Chemical industry, hospital, petroleum, winery, environmental inspection, food hygiene, soil, pesticide residues, paper making, electric power, mining, commodity inspection, etc.

 Ethylene oxide testing instrument configuration table for medical instruments:

 

Number

Name

Specifications

number of

1

Gas chromatograph

GC-7890 Host (SPL+FID)

1

2

Air generator

2L

1

3

Hydrogen generator

300ml

1

4

Nitrogen cylinders

Purity: 99.999% Cylinder + pressure reducing valve (purchased locally)

1

5

Dedicated column

Capillary column

1

6

The workstation

N2000

1

 

 

 

 

 


Product detail pictures:

Original Factory Sharp Edge Tester - GC-7890 Ditert-butyl Peroxide Residue Detector – Yueyang detail pictures


Related Product Guide:

Our advancement depends on the superior gear ,superb talents and consistently strengthened technology forces for Original Factory Sharp Edge Tester - GC-7890 Ditert-butyl Peroxide Residue Detector – Yueyang , The product will supply to all over the world, such as: Senegal, Anguilla, Gabon, Our items are exported worldwide. Our customers are always satisfied with our reliable quality, customer-oriented services and competitive prices. Our mission is "to continue to earn your loyalty by dedicating our efforts to the constant improvement of our merchandise and services in order to ensure the satisfaction of our end-users, customers, employees, suppliers and the worldwide communities in which we cooperate".
  • The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Letitia from Malaysia - 2017.10.23 10:29
    The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Erin from Guatemala - 2018.06.05 13:10
    Write your message here and send it to us