OEM Customized Liquid Loss Test Of Nonwovens. - YYP103A Whiteness Meter – Yueyang

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've got a really efficient group to deal with inquiries from prospects. Our purpose is "100% customer fulfillment by our product excellent, price & our group service" and enjoy a superb track record amid clientele. With many factories, we can easily deliver a wide selection of Resistance Meter, Heating Oven, Detection Of Button Strength Tester, Our ultimate goal is to rank as a top brand and to lead as a pioneer in our field. We are sure our successful experience in tool production will win customer's trust, Wish to co-operate and co-create a better future with you!
OEM Customized Liquid Loss Test Of Nonwovens. - YYP103A Whiteness Meter – Yueyang Detail:

Whiteness Meter is widely applied in papermaking, fabric, printing, plastic, ceramic and porcelain enamel, construction material, chemical industry, salt making and other testing department that need to test whiteness. DRK103A brightness meter also can test the paper’s transparency, opacity, light scatting coefficient and light absorption coefficient.

1.Test ISO whiteness (R457 whiteness) .It can also determine the fluorescent whitening degree of phosphor emission.

2. Test of lightness tristimulus values (Y10), opacity and transparency. Test light scatting coefficient and light absorption coefficient.

3. Simulate D56. Adopt CIE1964 supplement color system and CIE1976 (L * a * b *) color space color difference formula. Adopt d / o observing geometry lighting conditions. The diameter of diffusion ball is 150mm. The diameter of test hole is 30mm or 19mm. Eliminate the sample mirror reflected light by light absorbers.

4. Fresh appearance and compact structure; Guarantee the accuracy and stability of measured data with advanced circuit design.

5. LED display; Prompt operation steps with Chinese. Display statistical result. Friendly man-machine interface makes the operation simple and convenient.

6. Instrument is equipped with a standard RS232 interface so it can cooperate with the microcomputer software to communicate.

7. Instruments have a power-off protection; the calibration data is not lost when the power is cut off.

Brightness Meter is widely applied in papermaking, fabric, printing, plastic, ceramic and porcelain enamel, construction material, chemical industry, salt making and other testing department that need to test whiteness. PN-48B brightness meter also can test the paper’s transparency, opacity, light scatting coefficient and light absorption coefficient.

1.In accordance with GB3978-83: Standard lighting and lighting and observation conditions.

2.Simulate D56. The diffuse diameter is 150mm and test whole diameter is 30mm or 19mm. It uses light absorber to eliminate the influence caused by the specimen’s mirror reflecting light.

3.R457 whiteness optical spectral power distribution system in the peak wavelength 457nm, FWHM 44nm, RY10 optical system in line with the GB3979-83: object color measurement.

4.GB7973-87: Pulp, paper and paperboard diffuse reflectance factor assay (d/o method).

5.GB7974-87: paper and paperboard whiteness assay (d/o method).

6.ISO2470:paper and board Blu-ray diffuse reflectance factor method (ISO brightness);

7.GB8904.2:Pulp whiteness assay

8.GB1840:Industrial potato starch assay

9.GB2913:plastics whiteness assay

10.GB13025.2:Salt making industry general test method; whiteness assay

11.GB/T1543-88:Paper opacity determination

12.ISO2471:paper and cardboard opacity determination

13.GB10336-89:paper and pulp light scatting coefficient and light absorption coefficient determination

14.GBT/5950 construction material and non-metallic mineral products whiteness assay

15.GB10339 Citric acid whiteness and detection method

16.GB12911:Paper and paperboard Ink absorption determination

17.GB2409:Plastic yellow index. test method

1.zero drift: ≤ 0.1 %;

2.indication drift: ≤ 0.1 %;

3.indication error: ≤ 0.5 %;

4.repeatability error: ≤ 0.1 %;

5.specula reflection error: ≤ 0.1 %;

6.sample size: the test plane not less than φ30mm, the thickness of no more than 40 samples

7.Power: AC 220V ± 10%, 50HZ, 0.4A.

8.work environment: Temperature 0 ~ 40 ℃, relative humidity of not more than 85%

9.size and weight: 375 × 264 × 400 (mm), 16 kg

1.YYP103A brightness meter;

2.A power line; a black trap;

3.Two pieces of no fluorescent white standard plate;

4. One piece of fluorescent whitening standards board

5. Four light bulbs

6. Printing paper 4 volumes

7. A Power sample

8. Certification

9. Specification

10.Packing list

11.Warranty

12.Optional: constant pressure powder sampler.


Product detail pictures:

OEM Customized Liquid Loss Test Of Nonwovens. - YYP103A  Whiteness  Meter – Yueyang detail pictures


Related Product Guide:

Sticking for the perception of "Creating goods of high quality and making good friends with people today from all around the world", we constantly set the interest of shoppers to begin with for OEM Customized Liquid Loss Test Of Nonwovens. - YYP103A Whiteness Meter – Yueyang , The product will supply to all over the world, such as: Spain, French, Bangalore, If you give us a list of products you are interested in, along with makes and models, we can send you quotations. Please email us directly. Our goal is to establish long-term and mutually profitable business relationships with domestic and overseas clients. We look forward to receiving your reply soon.
  • This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Lynn from Mecca - 2017.11.11 11:41
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Mike from South Africa - 2018.06.03 10:17
    Write your message here and send it to us