Touch control color screen protective clothing blood penetration performance tester (hereinafter referred to as the measurement and control instrument) adopts the latest ARM embedded system, 800×480 large LCD touch control color display screen, amplifier, a / D converter and other devices all adopt the latest technology. It has the characteristics of high precision and high resolution, simulates the microcomputer control interface, and is easy to operate and greatly improves the test eff...
Used to test the resistance of medical protective clothing to the penetration of synthetic blood under specified test conditions.
GB 19082-2009
YY/T0700-2008;
ISO16603-2014
1. Large screen color touch screen, Chinese and English interface, menu operation mode.
2. High precision pressure sensor.
3. Import pressure regulating valve.
1. Display and control: color touch screen display and operation, parallel metal key operation.
2. Air source: 0.35 ~ 0.8MP; 30L/min
3. Pressure adjustment range: ...
The Inward Leakage Tester is used to test the leakage protection performance of respirator and protective clothing against aerosol particles under certain environmental conditions.
The real person wears a mask or respirator and stands in the room (chamber) with a certain concentration of aerosol (in the test chamber). There is a sampling tube near the mouth of the mask to collect the aerosol concentration in the mask. According to the requirements of the test standard, the human body complete...
The filter element vibration tester of respirator is designed and manufactured according to relevant standards. It is mainly used for vibration mechanical strength pretreatment of replaceable filter element.
Working power supply: 220 V, 50 Hz, 50 W
Vibration amplitude: 20 mm
Vibration frequency: 100 ± 5 times / min
Vibration time: 0-99min, settable, standard time 20min
Test sample: up to 40 words
Package size (L * w * h mm): 700 * 700 * 1150
26en149 et al
One electric control console and one ...
Refer to the following figures while reading this chapter.
Standards
ISO/DIS 22611 Clothing for protection against infectious agents-Test method for resistance to penetration by biologically contaminated aerosols.
Specifications
Aerosol generator: Atomizer
Exposure chamber : PMMA
Sample assembly : 2, stainless steel
Vacumm pump : Up to 80kpa
Dimension : 300mm*300mm*300mm
Power supply : 220V 50-60Hz
Machine Dimension: 46cm×93cm×49cm(H)
Net Weight:35kg
Preparation
Put the...
Used for testing all kinds of masks, medical protective clothing and other products.
GB 19082-2009
GB/T3923.1-1997
GB 2626-2019
GB/T 32610-2016
YY 0469-2011
YY/T 0969-2013
GB 10213-2006
GB 19083-2010
Instrument hardware:
1. Color touch-screen display operation, Chinese and English interface, menu operation mode.
2. Imported servo driver and motor (vector control), motor response time is short, no speed overrush, speed uneven phenomenon.
3. Ball screw, precision guide rail, long service lif...
Used for testing all kinds of masks, medical protective clothing and other products.
GB 19082-2009
GB/T3923.1-1997
GB 2626-2019
GB/T 32610-2016
YY 0469-2011
YY/T 0969-2013
GB 10213-2006
GB 19083-2010
1. Color touch -screen display operation, Chinese and English interface, menu operation mode.
2.Ball screw, precision guide rail, long service life, low noise, low vibration.
3. Equipped with high precision sensor, “STMicroelectronics” ST series 32-bit MCU, 24-bit A/D converter.
4....
The flame retardant property tester is used to measure the combustion rate of clothing textiles in the direction of 45. The instrument adopts microcomputer control, its characteristics are: accurate, stable and reliable.
GB/T14644
ASTM D1230
16 CFR Part 1610
1、Timer Range:0.1~999.9s
2、Timing Accuracy:±0.1s
3、Testing Flame Height:16mm
4、Power Supply:AC220V±10% 50Hz
5、Power:40W
6、Dimension:370mm×260mm×510mm
7、Weight:12Kg
8、Air Compressure:17.2kPa±1.7kPa
The instrument ...
The flame retardant tester for respirator is developed according to gb2626 respiratory protective equipment, which is used to test the fire resistance and flame retardant performance of respirators. The applicable standards are: gb2626 respiratory protective articles, gb19082 technical requirements for disposable medical protective clothing, gb19083 technical requirements for medical protective masks, and gb32610 technical specification for daily protective masks Yy0469 medical surgical mask,...
1. Ambient temperature: – 10 ℃~ 30 ℃
2. Relative humidity: ≤ 85%
3. Power supply voltage and power: 220 V ± 10% 50 Hz, power less than 100 W
4. Touch screen display / control, touch screen related parameters:
a. Size: 7 “effective display size: 15.5cm long and 8.6cm wide;
b. Resolution: 480 * 480
c. Communication interface: RS232, 3.3V CMOS or TTL, serial port mode
d. Storage capacity: 1g
e. Using pure hardware FPGA drive display, “zero” start-up time, power on can ru...
Used for testing the performance of materials and components in the design of protective clothing. The amount of vertical (normal) force required to cut through the test specimen by cutting the blade over a fixed distance.
EN ISO 13997
1. Color touch screen display, control, Chinese and English interface, menu operation mode;
2.Servo motor drive, high precision ball screw control speed;
3. Imported high precision bearings, small friction, high precision;
4. No radial swing, no runout and v...
The conductivity method and automatic timing device are used to test the penetration time of the fabric protective clothing for acid and alkali chemicals. The sample is placed between the upper and lower electrode sheets, and the conductive wire is connected to the upper electrode sheet and is in contact with the upper surface of the sample. When the penetrating phenomenon occurs, the circuit is turned on and the timing stops.
The instrument structure mainly includes the following parts:
1. U...
This instrument is specially designed to measure the liquid repellent efficiency of fabric protective clothing fabrics for acid and alkali chemicals.
1. Semi-cylindrical plexiglass transparent tank, with an inner diameter of (125±5) mm and a length of 300 mm.
2. The diameter of the injection needle hole is 0.8mm; the needle tip is flat.
3. Automatic injection system, continuous injection of 10mL reagent within 10s.
4. Automatic timing and alarm system; LED display test time, accuracy 0.1S.
5....
This instrument is used to test the hydrostatic pressure resistance of fabric protective clothing for acid and alkali chemicals. The hydrostatic pressure value of the fabric is used to express the resistance of the reagent through the fabric.
1. Liquid adding barrel
2. Sample clamp device
3. Liquid drain needle valve
4. Waste liquid recovery beaker
Appendix E of “GB 24540-2009 Protective Clothing Acid-base Chemical Protective Clothing”
1. Test accuracy: 1Pa
2. Test range: ...
YYPL1-00 Laboratory Rotary Digester ( cooking ,Laboratory digester for wood) is simulated in the production of steam ball working principle design, the pot body to make circumferential motion, make slurry for well mixed, suitable for papermaking laboratory to acid or alkali Zheng cook a variety of fiber raw material, according to different requirements of the process can be expected to plant size, thus for the production of process of the development of cooking process provides a basis. Can a...
PL15 Lab Pulp Screen is the pulping papermaking laboratory uses the pulp screen, reduces in the paper pulp suspending liquid in the papermaking experiment not to conform to the technological requirement impurity quantity, obtains the pure good thick liquid. This machine is the size for 270×320 the plate-type vibration pulp screen, may choose and match the different specification slit the lamina cribrosa, it is hits the good paper pulp, uses the mode of vibrations vacuum take-off function, car...
YY-PL27 Type FM Vibration-Type Lab-Potcher is used to simulate the production process rinse pulp of the experiment, can accomplish the pulp bleaching front wash, after washing, bleaching pulp bleaching process. The machine features: small size, low frequency vibration frequency from sieve continuously adjusts to high frequency, disassembled, easy to operate, can according to the pulp choose different frequencies in order to achieve the best effect for production, offer the most reliable exper...
Main technical parameters
Mechanical model (the data in brackets are actual paper)
2100(1600)
2600(2100)
3000(2500)
The max paper(A+B)×2(mm)
3200
4200
5000
The min paper(A+B)×2(mm)
1060
1060
1060
The max length of carton A(mm)
1350
1850
2350
The min length of carton A(mm)
280
280
280
The max width of carton B(mm)
1000
1000
1200
The min width of carton B(mm)
140
140
140
The max height of paper (C+D+C)(mm)
2500
2500...