Technical Parameters:
1. Children’s Diaper Test Parameters and Dimensions
1.1. U-shaped Sample Base Parameters:
B1: L:125±1mm W:122±1mm
B2: L:136±1mm W:135±1mm
B3: L:154±1mm W:152±1mm
1.2 Parameters of the Standard Liquid Addition Module:
M1: L:100±1mm W:80±1mm
M2: L:108±1mm W:85±1mm
M3: L:125±1mm W:95±1mm
1.3 Standard Test Pressurization Module:
Y1: L:100±1mm W:80±1mm
Y2: L:108±1mm W:85±1mm
Y3: L:125±1mm W:95±1mm
2. Adult Diaper Test Parameters and Dimensions
2.1. U-shaped Sample Base Parameters: L:319±1mm W:200±1mm
2.2 Parameters of the Standard Liquid Addition Module:
M1: L:170±1mm W:70±1mm
M2: L:170±1mm W:95±1mm
2.3 Standard Test Pressurization Module:
Y1: L:170±1mm W:70±1mm
Y2: L:170±1mm W:95±1mm
2. Liquid intake volume:
3.1 Baby diapers:
3.1.1 Small (S) size and below: (40±2)ml
3.1.2 Medium size (M) : (60±2)ml
3.1.3 Large (L) size and above: (80±2)ml
3.2 Baby diapers:
3.2.1 Small (S) size and below: (30±2)ml
3.2.2 Medium size (M) : (40±2)ml
3.2.3 Large (L) size and above: (50±2)ml
3.3 Adult diapers:
3.3.1: Moderate incontinence products: (100±2)ml
3.3.2: Severe incontinence products: (150±2)ml
3.4 Adult diapers:
3.4.1: Moderate incontinence products: (70±2)ml
3.4.2: Severe incontinence products: (100±2)ml
4. Pressurization pressure: 2.0±0.2 KPa, 4.0±0.2 KPa
5. Liquid addition flow rate: 480±5 ml/min (for children), 720±5ml/min (for adults)
6. Timing range: 0.00 to 9999.99 seconds
7. Heating range of the test solution: Room temperature +5℃ to 50℃
8. Power Supply: AC220V, 200W, 50Hz
9. Dimensions L×W×H: 320mm×220mm×500mm