Used for artificial aging test of various textile, dye, leather, plastic, paint, coatings, automotive interior accessories, geotextiles, electrical and electronic products, color building materials and other materials simulated daylight light can also complete the color fastness test to light and weather. By setting the conditions of light irradiance, temperature, humidity and rain in the test chamber, the simulated natural environment required for the experiment is provided to test the performance changes of the material such as color fading, aging, transmittance, peeling, hardening, softening and cracking.


Product Detail

Product Tags

Applications

Used for artificial aging test of various textile, dye, leather, plastic, paint, coatings, automotive interior accessories, geotextiles, electrical and electronic products, color building materials and other materials simulated daylight light can also complete the color fastness test to light and weather. By setting the conditions of light irradiance, temperature, humidity and rain in the test chamber, the simulated natural environment required for the experiment is provided to test the performance changes of the material such as color fading, aging, transmittance, peeling, hardening, softening and cracking.

Meeting Standard

AATCCTM16,169,ISO105-B02,ISO105-B04,ISO105-B06,ISO4892-2-A,ISO4892-2-B,GB/T8427,GB/T8430,GB/T14576,GB/T16422.2,JISL0843,ASTMG155-1,155-4,GMW3414,SAEJ1960,1885,JASOM346,PV1303,GB/T1865,GB/T1766,GB/T15102,GB/T15104.

Instruments Features

1.Suitable for high temperature, long time, sun, climate aging test; Equipped with revolution, alternating light and shade, rain test functions;
2. Set a variety of materials in advance of the climate and light resistance test standards, convenient for users to test, at the same time with programmable function, to meet the AATCC, ISO, GB/T, FZ/T, BS many national standards;
3. Large color touch screen display and operation, can monitor the irradiance, temperature, humidity online display dynamic curves; Multi-point monitoring and protection can realize unmanned operation of the instrument;
4. 4500W water-cooled long arc xenon lamp lighting system, real full solar spectrum simulation;
5. Distribution of energy automatic compensation technology, easy to achieve the time as the end of the test;
6.Equipped with 300 ~ 400nm; 420 nm; Two bands of light irradiance calibration and a large range of controllable technology, the other band can be monitored according to user requirements, to meet the aging test requirements of various materials;
7. Blackboard thermometer (BPT), standard blackboard thermometer (BST) and the sample at the same station (isometric) test, truly reflect the sample under test status, measured data in numbers, charts, curves and other ways displayed on the touch screen, without shutdown observation;
8. Large test capacity, one test is equivalent to six times of the air-cooled ordinary model test amount;
9. Each sample clip independent timing function;
10. Lower noise;
11. Double circuit redundancy design; Multi-point monitoring; With xenon lamp protection system, fault warning, self-diagnosis and alarm functions, to ensure the long-term uninterrupted smooth operation of the instrument;
12.The whole machine low-voltage components such as: button, relay, AC contactor and other selected German Schneider brand products.
13.With imported circulating water pump.
14. Equipped with two original imported lamps and three groups of imported DC regulated power supply.
15. All sample clamps are placed parallel to the lamp tube, without Angle, and sample clamps are correct.

Standard Parameters

1. Power supply: AC380V, three-phase four-wire, 50Hz,8KW

2. Tube: imported 4500W ultrafine water-cooled long arc xenon lamp, related color temperature of 5500K ~ 6500K;Diameter: 10mm;Total length: 450mm;Light arc length: 220mm, full daylight spectrum simulation, luminous efficiency up to 80%, good aging resistance, effective service life of nearly 2000 hours.Filter glass: placed between the light source and the sample and blue wool standard sample, so that the UV spectrum of stable attenuation.The transmittance of the filter glass is at least 90% between 380nm and 750nm, and it drops to 0 between 310nm and 320nm.

3. Xenon lamp power supply: AC380V,50Hz,4500W

4. Average service life: 1200 hours

5.The sample rack rotation speed: 3rpm

6.The sample rack drum diameter: 448mm

7. A single sample clip effective exposure area: 180mm×35mm, sample clip size: length 210mm, width: 45mm, clip thickness: 8mm.

8. In addition to placing a standard blackboard thermometer and an ordinary blackboard thermometer in the experimental chamber, 25 sample clamps can be placed evenly at the same time (sample clamps size: length 210mm, width: 45mm, maximum sample thickness: 8mm) to ensure that the single sample test volume is up to: 250.

9. A single sample clamp respectively timing range and accuracy: 0 ~ 999 hours 59 minutes + 1s

10. light cycle, dark period and accuracy: 0 ~ 999 hours 59 minutes ± 1S adjustable

11. Spray period and precision: 0 ~ 999 minutes 59 seconds + 1s adjustable

12.Spray method: the front and back of the sample spray, can choose the front or back alone spray

13. The test chamber temperature control range and accuracy: room temperature +5℃ ~ 48℃±2℃

Note: The temperature set by the instrument during operation is 5℃ higher than the ambient temperature to ensure that the instrument can reach the set temperature value smoothly.

14. Blackboard temperature control range and accuracy: BPT: 40℃ ~ 80℃±2℃, BST: 40℃ ~ 85℃±1℃

15. Humidity control range and accuracy: 30%RH ~ 90%RH±5%RH

16. Irradiance control range

The monitoring wavelength is 300 ~ 400nm (broadband) :(35 ~ 55) ±1W/m2 ·nm

Monitoring wavelength 420nm (narrow band) :(0.800 ~ 1.400) ±0.02W/m2 ·nm

Other passband can also be digital calibration real-time monitoring, automatic compensation and stability in the set value.

17. Illumination mode: parallel illumination. The distance between all tested samples and the lamp tube is 220mm.

18. Operation mode: revolution, light and shade alternating function

19. Cooling system: with imported circulating water pump, 3 stage water circulation flows between xenon lamp and filter glass, and through the heat exchange device cooling.

20. Dimensions: 1000mm×800mm×1800mm (L×W×H)

21. The total area is not less than: 2000mm×1200mm (L×W)

22.Weight: about 300kg

Configurations List

1. One main machine:
2. Sample clip and cover piece:

 ⑴ 27 sample clip, a single sample clip effective exposure area: 180×35mm;
(2) 27 covering sheets covering 1/2 of the total exposure area;
(3) 27 cover sheets covering the middle 1/3 of the total exposure area;
(4) Supporting cover the total exposure area of the left 2/3 of the cover 27 pieces;
⑸ supporting resin board 27 pieces;
Such as supporting a rotating frame;
3. Common blackboard thermometer (BPT)--- 1 Pcs
4.Standard blackboard thermometer (BST)--- 1 Pcs
5. Two sets of filter glass cylinder
6. Ultra-pure water machine for water cooling and sun drying
7. Imported long arc xenon lamp-- 2 pcs
8. Special lamp installation wrench-- 1 Pcs
9. Consumables: 1. 1 set of color changing gray cards; 2, GB blue standard 1 group (level 1 ~ 5)

Options

1. Filter glass sheet; Heat filter glass sheet;
2. Quartz filter glass cylinder;
3. Imported long arc xenon lamp;


  • Previous:
  • Next:

  • Write your message here and send it to us