YY817A Rain‑Tower Testing Machine(ISO 24232 )

Short Description:

Instrument Purpose

It is used to determine the rainproof performance of rainproof garments by means of a static mannequin exposed to artificial rainfall. It applies to testing jackets, trousers, coats and onepiece or twopiece suits.

It is not applicable for testing the garment resistance to other weather conditions such as snow, hail or strong wind.

 

Applicable Standards

BS EN 14360:2004, ISO 242312024 and other standards.

 

Product Features

1. Large screen color touch screen with Chinese English bilingual menu operation interface.

2. Equipped with the self developed operating system; General Purpose Test Instrument Software V1.0.0.

3. The base adopts space aluminum frame; viewing surfaces are made of plexiglass; all other water contact components are SUS304 stainless steel for long term rust free service.

4. Standard compliant test mannequin with adjustable standing angle and swingable arms.

5. The rainfall system is equipped with a high precision pump liquid control system.

6. 25 channel humidity sensors collect signals and connect to the dedicated test system to monitor real time wetting status of specimens under rain impact.

7. The water receiving tray adopts an electric transfer device for rapid response.

8. Modular frame design facilitates transportation, handling and installation.

9. Two temperature sensors measure ambient temperature and water temperature inside the circular water tank respectively.

10. Separated design of electric control cabinet and main unit eliminates potential safety hazards caused by water contact.


Product Detail

Product Tags

Technical Parameters

1. Height of circular water tank above ground: ≥5000 mm

2. Nozzles mounted at the bottom of circular water tank: 682 units (1000 units/m²); nozzle aperture: 0.6 mm; centretocentre spacing between nozzles: 34 mm

3. Water level of circular water tank: (45±5) mm; an overflow outlet is set above 45 mm

4. Waterdrop diameter: approx. 5 mm; water flow rate: (450±50) L/(m²·h)

5. Temperature sensor: measuring range ≤100 ℃; resolution: 0.1 ℃; accuracy: ±0.5 ℃

6. Mannequin

Height: (1820±40) mm

Chest circumference: (1000±60) mm

Backwardtilt angle: 0~10°

Arm angle relative to true vertical direction: 20~30°

Composed of head, torso, abdomen, hip, arms, hands, straight legs and feet; movable arms

7. Humidity sensor

Quantity: 25 channels

Measuring range: (20~99) %RH

8. Test duration: <100 h

9. Overall dimension (L×W×H): 1300 mm × 1300 mm × 5500 mm

10. Weight: approx. 300 kg